Heart devices: how do a pacemaker, an ICD and a CRT-D differ?
What a pacemaker, an ICD, a CRT-P and a CRT-D do, how many leads they have and who may need them: a short table and a simple explanation.
- 8 min read
- Sources: 10
- Updated: 10 November 2026
Reviewed by a doctorSherzod Nasirovich SabirovCardiologist-arrhythmologistShort answer
A pacemaker (heart stimulator) sends an electrical signal to the heart when it beats too slowly. An ICD (cardioverter-defibrillator) stops a life-threatening fast rhythm. CRT coordinates the work of the ventricles: a CRT-P only paces, while a CRT-D also defibrillates. According to the EHRA patient website, the difference lies in what the device does and in the number of leads. Your doctor decides together with you which device is needed.
In this article sections: 7
- How do a pacemaker, an ICD, a CRT-P and a CRT-D differ, in a table?
- Who may need a pacemaker?
- What does an ICD do and who needs one?
- Why are CRT-P and CRT-D needed?
- Leadless pacemaker, S-ICD, AED and vest: are these the same devices?
- How is a device chosen and when is emergency help needed?
- Frequently asked questions
How do a pacemaker, an ICD, a CRT-P and a CRT-D differ, in a table?
According to the EHRA patient website (myrhythmdevice.org), these devices consist of two parts. The generator is a small metal box that holds the battery and the electronic circuit. The lead is a thin, insulated wire that connects the generator to the heart.
| Device | What it does | Leads | Usual reason |
|---|---|---|---|
| Single-chamber pacemaker | Sends signals to a slow heart | 1 | Slow rhythm, for example in atrial fibrillation |
| Dual-chamber pacemaker | Coordinates the atrium and the ventricle | 2 | AV block |
| ICD | Stops a dangerous fast rhythm | 1–2 | Has had a dangerous ventricular arrhythmia, or is at high risk of one |
| CRT-P | Coordinates the two ventricles | 2–3 | Heart failure |
| CRT-D | Coordinates and delivers shocks | 3 | Heart failure and a risk of dangerous arrhythmia |
The atrium is the upper chamber of the heart, and the ventricle is the lower chamber. AV block means the signal fails to pass from the atrium to the ventricle. The table gives a general idea; the exact decision is made by a specialist.
Who may need a pacemaker?
According to EHRA, a pacemaker monitors the rhythm all the time and sends a signal only when the heart beats too slowly. It may be needed in sinus bradycardia (when the sinus node, which starts the rhythm, works slowly) and in AV block.
- Single-chamber: one lead. If the signal starts in the sinus node but is slow, the lead is placed in the right atrium. If the rhythm is slow and does not start in the sinus node, for example in atrial fibrillation, it is placed in the right ventricle.
- Dual-chamber: two leads, in the right atrium and the right ventricle. It is used in AV block and coordinates these two chambers.
If possible, the cause is dealt with first, for example a medicine that slows the rhythm is stopped; the doctor decides this. A pacemaker may be needed when this is impossible or not enough. According to the ACC summary of the 2021 ESC/EHRA guidelines, not everyone who is found to have a slow rhythm needs a pacemaker.
What does an ICD do and who needs one?
An ICD (implantable cardioverter-defibrillator) monitors the rhythm all the time. According to EHRA, it stops a life-threatening ventricular arrhythmia with fast pacing or a shock (a brief electrical impulse). These rhythms are ventricular tachycardia (the heart beats very fast) and ventricular fibrillation (the ventricles quiver instead of pumping blood). An ICD placed through a vein can also send signals to a slow heart, like an ordinary pacemaker.
EHRA distinguishes two situations:
- Secondary prevention: the person has a confirmed or suspected dangerous ventricular arrhythmia.
- Primary prevention: there has been no such arrhythmia, but the risk is high because of a diagnosed heart disease, sometimes because of a disease or genetic change found in the family.
The exact criteria depend on the type of disease, and a specialist assesses them.
Why are CRT-P and CRT-D needed?
In heart failure, the ventricles may stop contracting at the same time, and this may make symptoms worse. The cause of this may be left bundle branch block, that is, a blockage of one of the signal pathways inside the heart.
According to EHRA, in some severe cases where medicines are not enough, CRT (cardiac resynchronization therapy) may be needed. It coordinates the right and left ventricles, so that each beat becomes more effective.
A CRT-P (a “biventricular pacemaker”) only paces. A CRT-D, with three leads, combines resynchronization with defibrillation. The choice depends on the risk of dangerous arrhythmia, and a specialist decides it.
According to the ACC summary of the 2021 ESC/EHRA guidelines, CRT is recommended in heart failure with symptoms if there is sinus rhythm, LVEF ≤ 35 %, QRS ≥ 150 ms and left bundle branch block. LVEF shows how much blood the left ventricle pumps out in one beat, and QRS is a wave on the ECG.
- Device
- Right atrial lead
- Right ventricular lead
- Left ventricular lead
Leadless pacemaker, S-ICD, AED and vest: are these the same devices?
No, even though the names are similar, these are different things:
- Leadless pacemaker: only a generator, placed in the right ventricle through the femoral vein. It is only for those who need single-chamber pacing of that chamber.
- S-ICD (subcutaneous ICD): its box sits near the armpit and its lead lies under the skin. It only delivers shocks, does not pace, and its incision is larger.
- AED: an automated defibrillator in public places. Even a person with no special training can use it.
- Wearable defibrillator vest: usually worn for a short period.
How is a device chosen and when is emergency help needed?
According to the ACC summary of the 2021 ESC/EHRA guidelines, the decision is made jointly: the evidence, the individual risks and benefits, your wishes and the goals of treatment are taken into account. According to the same summary, infection occurs more often with CRT or an ICD than with an ordinary pacemaker. It also occurs more often in device replacement and upgrade procedures.
Questions you can ask your doctor:
- Which device is being recommended for me, and why?
- Is there another way of treatment?
- What checks will be needed after it is implanted?
Frequently asked questions
Are a pacemaker and an ICD the same device?
No. According to EHRA, a pacemaker sends a signal when the heart beats too slowly, while an ICD stops a life-threatening fast rhythm. An ICD placed through a vein can also do the job of a pacemaker, but a pacemaker does not deliver shocks.
How does a single-chamber pacemaker differ from a dual-chamber one?
A single-chamber pacemaker has one lead, which sits in the right atrium or the right ventricle. A dual-chamber pacemaker has two leads, and they coordinate these two chambers. According to EHRA, the dual-chamber type is used in AV block.
What is the difference between a CRT-P and a CRT-D?
Both coordinate the work of the ventricles in heart failure. A CRT-P only paces, while a CRT-D can also deliver a shock. The choice depends on the risk of dangerous arrhythmia, and a specialist decides it.
How long does the battery last?
The sources give different figures. Pacemaker: EHRA 7–10 years, NHS 6–7 years. ICD: EHRA on average 7–10 years, NHLBI 5–7 years. A CRT-D is often replaced sooner; NHLBI gives about 4 years. Your doctor will tell you about your device.
What checks are done after the device is implanted?
The sources differ here too. EHRA: the first check at 2–12 weeks, then usually once a year. NHS (pacemaker): at about 6 weeks, at 3–6 months, then at least once every 12 months. NHLBI (ICD): at least once every 6 months. Follow your own doctor’s schedule.
SourcesSources: 10
- myrhythmdevice.orgEHRA (myrhythmdevice.org): How does a pacemaker work? (opens in a new window)
- myrhythmdevice.orgEHRA: The different types of pacemakers (opens in a new window)
- myrhythmdevice.orgEHRA: When do I need a pacemaker? (opens in a new window)
- myrhythmdevice.orgEHRA: How does an ICD work? (opens in a new window)
- myrhythmdevice.orgEHRA: The different types of ICDs (opens in a new window)
- myrhythmdevice.orgEHRA: When do I need an ICD? (opens in a new window)
- acc.orgACC: 2021 ESC/EHRA guidelines on cardiac pacing (opens in a new window)
- nhs.ukNHS: Pacemaker implantation (opens in a new window)
- nhlbi.nih.govNHLBI: Defibrillators (opens in a new window)
- nhlbi.nih.govNHLBI: Living with an ICD (opens in a new window)
This is general information and does not replace diagnosis or treatment. If you have symptoms, see a doctor.